Provide cubicle curtain mesh that conforms to the following requirements of regulatory agencies and the quality control of the diamond drapery company inc.
Cubicle curtain mesh requirements.
Two piece rolled edge rust proof aluminum.
Hcs cubicle curtains 1 pattern.
Improperly designed systems might obstruct the sprinkler spray from reaching the fire or might shield the heat from the sprinkler.
Fire performance characteristics 1.
Many options are available to the designer including but not limited to hanging the cubicle curtains 18 in.
Medline will use 20 of mesh unless instructed otherwise.
Spaced not more than 6.
For the proper operation of sprinkler systems cubicle curtains and sprinkler locations need to be coordinated.
46 cm below the sprinkler deflector.
Curtains to have 110 percent fullness width to be determined by length of track to ensure proper enclosure.
As selected by architect from manufacturer s full range of available fabrics.
Provide mesh that conforms with nfpa 701 fire tests for flame and resistant.
1 3 cm diagonal mesh or a 70 percent open weave top panel that extends.
As selected by architect from manufacturer s full range of available colors.
White nylon mesh with 1 2 diagonal openings.
Curtains can be ordered with or without 20 inches of mesh at the top.
Provide all cubicle curtains from a single source.
Please note that if using less than 20 of mesh it is recommended to have approval from the local fire marshal who is responsible for determining acceptable mesh height standards.